Sign In | Join Free | My tjskl.org.cn |
|
Brand Name : GENY
Model Number : YC99T-5C pro
Certification : ISO, CE
Place of Origin : China
MOQ : 1pcs
Price : negotiate rates
Payment Terms : T/T,L/C,D/P,T/T
Supply Ability : 30 PCS per month
Delivery Time : 6~8weeks
Packaging Details : Plywood case
AC Voltage Output max. Load : 50VA / phase
AC Current Output Stability : 0.01%/2min
Frequency Output Accuracy : 0.002 Hz
Main Unit Weight : 38kg
• Three-phase fully automatic or manual-control energy-meter test system with reference standard and integrated current and voltage source.
• It can calibrates basic error, creeping, starting, and standard deviation automatically or single-step manually; automatic calibration sequences can be user’s request.
• Verifies and calibrates max 3 units single-phase meters,or three-phase meters complying with MS IEC 62052-11, MS IEC 62053-21, 62053-22, 62053-23, 62053-31, MS IEC 62063-61, and BS 568.
• Current source outputs up to 3 × 120 A continuously for a minimum of 8 hours.
• Current and voltage sources selectable independently; current, voltage, and phase shift adjustable with high accuracy on a per-phase basis.
• Optional capability to test 3 three-phase close-link meters.
• Generates 2nd–63rd harmonics; functions as a harmonic source.
• Automatic operation via predefined load points using onboard keyboard, mouse, or external laptop.
• Displays voltage, current, phase angle, vector diagram, waveform, harmonics, etc.
• Current output can be customized.
• 32 GB internal memory for customer data and measurement results.
• Saved test results uploadable to external laptop via Ethernet.
• Compact, robust design with long-term stability.
AC Voltage Output | Output range | 57.7V, 100V, 220V, 380V |
Adjustment range | (0 ~ 120)%RG | |
Adjustment degree | 0.01%RG, 0.1%RG, 1%RG; 10%RG are optional | |
Stability | 0.01%/2min | |
Distortion | ≤0.2% (Non-capacitive load) | |
Output max. Load | 50VA / phase | |
Measurement accuracy | 0.05%RG | |
| Output range | 50mA, 200mA, 1A, 5A, 20A, 150A |
AC Current Output | Adjustment range | (0 ~ 120)%RG |
Adjustment degree | 0.01%RG, 0.1%RG, 1%RG; 10%RG are optional | |
Stability | 0.01%/2min | |
Distortion | ≤0.2% (Non-capacitive load) | |
Output max. Load | 10VA/50mA,20VA/0.02A,1A,5A,50VA/20A, 150VA/100A | |
Measurement accuracy | 0.05%RG | |
| stability | 0.01%RG/2min |
Power Output | Active & Reactive power measurement accuracy | 0.05%RG |
| Phase Output | |
Phase Output | Adjustment degree | 10°, 1°, 0.1°, 0.01° are optional |
Resolution | 0.01° | |
Accuracy | 0.05° | |
| Adjustment range | -1 ~ 0 ~ +1 |
Power Factor Output | Measurement resolution | 0.0001 |
Measurement accuracy | 0.0005 | |
| Adjustment range | 40Hz ~ 70Hz |
Frequency Output | Output adjustment degree | 1Hz, 0.1Hz, 0.01Hz, 0.001Hz are optional |
Resolution | 0.001 Hz | |
Accuracy | 0.002 Hz | |
| Harmonic times | 2 ~ 63 times |
Harmonic Set Up | Harmonic content | ≤40% |
Harmonic phase | 0° ~ 359.999° | |
Harmonic set up error | 2-51times:≤±0.1%(optional 63times,±0.1%) | |
| Active PF≥0.5 | ±0.5%RD |
Energy Error Measurement | Active PF=1 | ±0.01%RD |
Reactive PF≥0.5 | ±0.1%RD | |
Reactive PF=1 | ±0.2%RD | |
| Power Supply | AC 220V±15% or 110V±15%, 50Hz~60Hz |
General Specification | YC99T-5C: 38kg |
![]() |
YC99T-5C Pro Portable Meter Test Equipment Images |